The following questions arose from the participants in the recent ICPI webinar, "Preventing Silica Exposure of the Jobsite." After consultation with the presenters, Rob Bowers summarized these responses.  The webinar recording is available on the Webinars and On-Demand Learning page. The recording is FREE to members as part of the Contractor Webinar Series and costs $70 for non-members.

robbw.jpg

Respirable Crystalline Silica References

Answers to Post-Webinar Questions:

1. Is there a template available we can follow to implement the safety program/manual for silica?
Currently, contractors can make use of the following generic construction industry tools.

2. Regarding OSHA's statement that certain tasks on table one do not require medical monitoring IF an employee does not perform that or other tasks which require an APF 10 for more than 30 days...Do we have an interpretation of is that 30 instances or a total of 30 days with more than 240 hours of work exposure (totaling 30 days)?
The Small Entity Compliance Guide states, “Employers must make an initial or periodic medical examination available to employees who will be required by the silica standard to wear a respirator for 30 or more days per year in the upcoming year (the next 365 days). "If the employee is required to wear a respirator at any time during a day, even if it is just for a few minutes, that counts as one day of respirator use.” 

If an employee is required to perform a task that requires a respirator, as a contractor and employer, you will be required to comply with the related OSHA Standards.
a. A Respiratory Program per 29 CFR 1910.134 Federal OSHA Standard. The Respiratory Program includes:

  • Medical evaluation questionnaire

  • PFT – Pulmonary Function Test

  • Respirator fit test

  • Written respiratory program with documented training

b. In addition, the Silica Standard 29 CFR 1910.1053 and 29CFR 1926.1153 program requirements include the respiratory program listed above AND the following:

  • Physical Exam

  • TB Test

  • Chest X-Ray – must be read by a NIOSH-certified B Reader

  • Written silica exposure control plan with documented training

3. Does the IQ saw meet the requirement of not having to have a respirator for a standard paver cut and is there written data to support the requirement which can be used as part of an employer’s written silica exposure control plan?
iQ Powertools has reported they have objective air monitoring test data to confirm that the tool, when used per manufacturer’s recommendations, meets the OSHA Silica Permissible Exposure Limit (PEL). Contact iQ Powertools to obtain this test data.

When a manufacturer tests its equipment, if the work practice and materials used match the job site conditions, OSHA will allow this data to be used as objective data as part of a written silica exposure control plan. Remember, to comply with the standard, OSHA requires an employer to have a written silica exposure control plan.

Since cutting concrete with a vacuum assisted saw is not listed in Table 1 of the standard, the employer must follow the Alternative Exposure Control Methods to determine the levels of respirable crystalline silica that employees are exposed to. This can be done using the performance option; or the scheduled monitoring option as directed by the standard. Following the performance option will require Objective Data that demonstrates employee exposure to respirable crystalline silica associated with a particular product or material or a specific process, task, or activity. The data must reflect workplace conditions, that closely resemble, or could result in higher exposures, than the processes, types of material, control methods, work practices, and environmental conditions in the employer’s current operations.

Examples of objective data are information such as:
a. Air monitoring data from industry-wide surveys;
b. Calculations based on the composition of a substance;
c. Area sampling results and exposure mapping profile approached; and
d. Historical air monitoring data collected by the employer.

4. Do smaller residential projects have the same rules and regulations as larger commercial projects?
Yes. The Federal and state OSHA standards apply to all employers, large and small, nationwide. It applies to all projects, large and small, nationwide. In the past, you may have worked on smaller residential projects and never saw an OSHA inspector. Smaller residential projects are harder for them to find. But, if they drive by and see you working, they will probably stop and do an inspection. ICPI recommends that you be prepared, comply with the standard, have a silica exposure program in place and protect the health of your workers.

5. What about homeowners that are working on their own homes?
OSHA standards do not apply to homeowners working on their own property or to contractors who work by themselves. “29 U.S.C. § 654, 5(a)1: Each employer shall furnish to each of his employees employment and a place of employment which are free from recognized hazards that are causing or are likely to cause death or serious physical harm to his employees.” The caveat is that OSHA does not cover workers who are not employees. However, OSHA has determined that exposure to respirable crystalline silica at a level under 50 µg/m³ over an eight-hour period time weighted average (TWA) is a safe Permissible Exposure Limit (PEL). It would make sense that homeowners and single contractors not jeopardize their health and work to be below the PEL.

6. What if you are using a table saw but dry cutting with a vacuum attached? 
a. Is this acceptable?
As mentioned above, dry cutting concrete with a vacuum system is not listed in Table 1 so you would have to comply with the Alternate Exposure Control Methods. Determining if this would reduce the exposure level below the Permissible Exposure Limit (PEL) can only be determined after Air Monitoring Data is collected using a worker performing that task with the equipment, materials and site conditions in question. It may be possible to confirm the operator, and those in the immediate area, are safely under the Permissible Exposure Limit (PEL), if you have objective test data.

b. Can you use a respirator in addition to the vacuum?
Use of a respirator will reduce the exposure level by the respirator’s Assigned Protection Factor (APF). As an example, if a worker is exposed to an environment that has a measured respirable crystalline silica level of 400 µg/m3 per 8-hr day TWA and they use a respirator with an APF of 10, the calculated exposure level will be 40 µg/m3 per 8-hr day TWA which is less than the regulated PEL. However, if the worker uses a respirator for more than 30 days a year, they will have to comply with 29 CRF 1910.134 - Respiratory Protection. In addition, the employer must comply with the additional respirator requirements from the Silica Standard. (See Question 2.b)

7. I thought I was told that none of the tools present in today’s markets provide the necessary filtration to ensure compliance with the new PEL limits.
a. Is this true?
False. There are many tools with vacuums attached or integrated, from various manufacturers, that could be used to drill, grind, chip, and cut concrete, asphalt and masonry materials that will safely keep an employee under the 50 µg/m³ over an eight-hour period time-weighted average.

b. If so, then even if you have vacuum saws you must then have respirators?
The tools available are getting better and better at reducing the exposure to respirable crystalline silica. If it can be demonstrated with Air Monitoring Data collected using a worker performing the task with the equipment, materials and site conditions in question, that exposure levels are below the Permissible Exposure Limit (PEL) then a respirator is not required. However, if the dust reduction systems are not function at 100% effectiveness or the conditions change from those present when the Air Monitoring Data was collected, it is possible that an OSHA inspection could conduct a test and determine the exposure level is more than the PEL. That is why ICPI recommends when cutting concrete with a saw, the use of a respirator is a good practice.

8. When OSHA’s Table One does not give specific control method of using a commercial vacuum system for some tasks, and does for others, may we assume we can use a commercial vacuum system IF we obtain test results, as OSHA outlines, that would prove we can perform the task below the PEL?
Yes. As mentioned previously, if the exposure control method is not included in Table 1, the Alternate Exposure Control Method must be utilized. Table 1 currently does not include dry cutting concrete with a saw using a vacuum dust reduction system. The first step of the alternative exposure control method is to determine the levels of respirable crystalline silica that employees are exposed to. This can be determined by collecting Air Monitoring Data using a worker performing that task with the equipment, materials and site conditions in question. These results may prove the exposure levels are below the Permissible Exposure Limit (PEL) and even the Actionable Exposure Limit (AEL). However, it will still be necessary to comply with the Alternate Exposure Control method and, “use engineering and work practice controls, to the extent feasible, to limit employee exposures to the PEL, and supplement the controls with respiratory protection when no other alternative is available. As well as keep records of employee exposure to respirable crystalline silica.”

9. Does the protection requirement pertain to just the individual using the saw to cut & not installers that are not in the immediate area?
Part of the written control program should contain information on methods used to restrict access to the area. The plan must include a description of the procedures used to restrict access to work areas, when necessary, to limit the number of employees exposed to respirable crystalline silica and the levels to which they are exposed, including exposures generated by other employers or self-employed workers. When Table 1 requires respiratory protection, employers must provide respirators to all employees engaged in the task.

It would make sense that persons working in the restricted area would need the same level of protection afforded to the worker whose task was generating the respirable crystalline silica.

10. How do you perform an air monitoring test?
An air monitoring test is typically conducted using the following equipment: Air sample pump, calibrator or rotameter, air sampling cassette filter, cassette filter holder, cyclone, tubing and clip. A small tube runs from the pump over the shoulder and is clipped on the chest or collar near the worker’s breathing area. This test can be done with or without a respirator. The worker them performs the task that needs to be analyzed. As the pump runs, air taken from the vicinity of the worker’s breathing area is filtered to collect all dust present. Once the testing is complete, the length of time the pump runs and the volume of air sampled is then recorded. The cassette filter is then analyzed in a lab to determine the mass of respirable crystalline silica captured. This number is then factored to consider the volume of air the worker would breathe in an 8-hour day compared to the volume of air sampled by the pump over the period of time that the air sample was taken.

Here is a link to a video from ALS Global that will be useful to contractors wanting to understand how to use air monitoring equipment to perform a test themselves: https://www.youtube.com/watch?v=O5knJEGGa7k(link is external)

11. Isn't it true that the current studies show that even cutting with a vacuum saw or wet you still would be required to have a respiratory system? 
There are numerous studies that have been done with results both above and below the Permissible Exposure Limit (PEL). Remember, if an employer has objective test data to confirm the tools, work practices and materials being used, creates and exposure level under the Permissible Exposure Limit (PEL) then no respirator is required.

The intent of the OSHA Silica Standard is to limit employees’ exposure to silica and keep them in a safe work environment. OSHA has determined that 50 µg/m³ over an eight-hour period time-weighted average (TWA) is a safe, maintainable limit.

12. Does an N95 Mask count as a respirator? 
Yes. OSHA recognizes the N95-rated, 2 strap mask as a respirator with an Approved Protection Factor (APF) of 10. Please reference OSHA’s Small Entity Compliance Guide for the Respiratory Protection Standard as well as 29 CRF 1910.134 - Respiratory Protection standard. As with any respirator, they must be fit tested. Refer to Question 2 for more information regarding a respiratory program.

Air Purifying Respirators.jpg

13. What about Techniseal NextGen?
Techniseal’s NextGel stabilized joint sand is reported by the manufacturer to generate substantially less dust when it is spread and compacted into the joint compared to other joint sand. Obtaining objective data from the manufacturer could confirm this. Alternately, collecting Air Monitoring Data using a worker spreading and compacting the joint sand with the equipment, materials and site conditions in question would be needed to confirm the exposure level.

14. What is the contact information for lab that does air monitoring testing? 
There are three main components to get Objective Data, i.e. a silica air monitoring test report.

  1. Obtain air monitoring equipment (air pump, calibrator, air sampling cassette, hoses and a clip)

  2. Conduct air monitoring tests – which is typically done by Industrial Hygienists.

  3. Analyze the collected samples.

Here are links to two Industrial Hygiene companies that can help you obtain Objective Data.

15. Are there procedures to clean up after cutting pavers?
a. If wet cutting, what is the suggested clean up procedure of the slurry?

If you are using a wet table saw, remove the slurry from the saw and allow it to dry, solidify and then dispose of with other site waste. Handle with care as to not reintroduce the dust into the atmosphere where it could be inhaled by someone. If cutting in place with a saw that has a water attachment and the slurry is on the paver surface, use large volumes of water to rinse before the slurry dries and permanently stains the paver surface. Scrub with a stiff bristle brush if necessary.

b. Once dust is collected, what is the procedure for proper disposal?
The Housekeeping section of the standard requires that when cleaning up dust that can contribute to employee exposure to respirable crystalline silica, employers must:

  • Not allow cleaning by dry brushing and sweeping, unless methods such as wet sweeping and HEPA-filtered vacuuming are not feasible;

  • Not allow cleaning of surfaces or clothing with compressed air, unless the compressed air is used together with a ventilation system that effectively captures the dust cloud or no other cleaning method is feasible.

This section of the written plan would include cleaning methods that are acceptable (e.g., wet sweeping), cleaning methods that are unacceptable because acceptable cleaning methods are feasible (e.g., dry sweeping or blowing), and special instructions (e.g., use local exhaust ventilation if compressed air must be used). Hygiene-related subjects, such as not using compressed air to clean clothing, could also be addressed in this section of the written exposure control plan.

Remember the intent of the OSHA Silica Standard is to limit employees’ exposure to silica and keep them in a safe environment. Care and common sense apply to the proper disposal of the collected dust. Do not reintroduce the dust into the atmosphere where it could be inhaled by someone. Here are some options.

  1. Mix the collected dust with water and allow to dry and solidify, then dispose of with other site waste.

  2. Put the collected dust into a sealed container or trash bag for disposal with other site waste.

  3. Mix it with moist native soil on the job site.

Additionally, the paver industry has used the terminology “sweeping” joint sand. To help differentiate the clean-up task from the necessary interlocking concrete pavement construction step, it is suggested that you use the terminology “applying” or “spreading” joint sand. Use of the term sweeping will probably attract unnecessary attention from an OSHA inspector because of the almost complete prohibition on dry sweeping. Keep in mind, the Permissible Exposure Limit still needs to be considered. 

Have additional questions regarding silica? Please contact ICPI, at 703-657-6900.